ULTRAPROBETM 100INSTRUCTION MANUALVOLUME 1.3
2. ELECTRIC ARC, CORONA, TRACKING DETECTIONThere are three basic electrical problems that are detected with the Ultraprobe 500:Arcing: An arc occurs
3. DETECTING BEARING WEARUltrasonic inspection and monitoring of bearings is by far the most reliable method for detecting incipient bearingfailure.
DETECTING BEARING FAILURECOMPARATIVE TESTING. The comparative method involves testing two or more similar bearings and "com-paring" potenti
5. LOCATING FAULTY STEAM TRAPSAn ultrasonic test of steam traps is a positive test. The main advantage to ultrasonic testing is that it isolates thea
THERMOSTATIC TRAPS (bellows & bimetallic) operate on a difference in temperature between condensate andsteam. They build up condensate so that th
6. LOCATING FAULTY VALVESUtilizing the contact (stethoscope) module in the Ultraprobe, valves can easily be monitored to determine if avalve is opera
ULTRASOUND TECHNOLOGYThe technology of ultrasound is concerned withsound waves that occur above human perception.The average threshold of human percep
SPECIFICATIONSConstruction: Hand held ABS pistol type ultrasonic processorstainless steel sensor enclosuresCircuitry: SMD/Solid State hybrid hetrodyne
SAFETY ADVISORY PLEASE READ BEFORE USING YOUR INSTRUMENT.WARNINGImproper use of your ultrasonic detector may result in death or seriousinjury. Obser
NEED HELP???HAVE QUESTIONS??AT UE SYSTEMS, WE ARE DEDICATED TO SUPPORTING OURULTRAPROBE USERS.OUR STAFF HAS YEARS OF FIELD EXPERIENCE AND ISSTANDING R
The ULTRAPROBE 100 provides easy, accurate leak detection and mechanical inspection through advancedultrasonic technology.Before you begin testing, it
2. SCANNING MODULEThis module is utilized to receive air-borne ultrasound such asthe ultrasounds emitted by pressure leaks and electrical discharges
To use the WARBLE TONE GENERATOR:1. Turn Tone Generator on by selecting either "LOW" for a low amplitude signal (usually recommended forsma
-4-ULTRAPROBE APPLICATIONS1. LEAK DETECTION This section will cover airborne leak detection of pressure and vacuum systems. (For information co
-5-B. TO CONFIRM A LEAK: Position the Scanning Module, or the rubber focusing probe (if it is on the scanning module) close to thesuspect leak
-6-D. LOW LEVEL LEAKSIn ultrasonic inspection of leakage, the amplitude of the sound often depends upon the amount of turbulencegenerated at the leak
The Tone Test incorporates two basic components: a TONE GENERATOR (an ultrasonic transmitter) , and theScanning Module in the Ultraprobe. To conduct